Filter Results By:

Products

Applications

Manufacturers

Data Acquisition

senses the physical, represented as an analog signal, that is then converted to digital data. AKA: DAQ

See Also: Data Acquisition Systems, PCI Data Acquisition, DAQ, Digitizers


Showing results: 1321 - 1335 of 1542 items found.

  • PXI-5154, 1 GHz, 2 GS/s, 8-Bit, 8 MB/ch, PXI Oscilloscope

    780319-01 - NI

    1 GHz, 2 GS/s, 8-Bit, 8 MB/ch, PXI Oscilloscope—The PXI‑5154 is ideal for acquisition and characterization of fast, nanosecond-edge speeds. It is well-suited for automated test and data streaming applications in the consumer electronics, semiconductor, aerospace/defense, and life sciences industries. The PXI‑5154 also comes equipped with up to 256 MB of memory per channel to provide high, sustained sample rates over extended data capture windows. This digitizer, optimized for automated test, uses a high-throughput bus to lower test times, provides picosecond-level synchronization among modules, and integrates with the entire suite of NI hardware, so you can build and customize a complete mixed-signal or high‑channel‑count test system.

  • I-V Measurement Systems

    Photo Emission Tech., Inc.

    The I-V Curve Data Acquisition includes a fixture for holding cells for testing (see Figure 1 below). This fixture can accommodate cells from small to up to 100 mm x 100 mm. Adjustable cell stops, in the X & Y-axis, are provided to consistently locate the cells for testing. Two micro-manipulators are provided as shown in Figure 1. Each micro-manipulator has two spring loaded contacts to allow 4-wire measurement even for cells that have top contacts only. Two back-side voltage contacts are embedded in the Plate (galvanically isolated from the Plate) and make good electrical contact when the cell is held down by vacuum to the plate. All voltage and current probes are gold-plated. The cell is held down with vacuum during testing (built-in vacuum pump).

  • Network OTDR

    NFO series - Radiantech, Inc.

    The NFO OTDR unit injects the laser pulse into the fiber under test and picks up scattered and reflected optical signals by an avalanche photodiode (APD). The unit accepts remote commands from Internet to control all related timing and data acquisition processes. Maximal three wavelengths are available at the NFO with options on 1310, 1490, 1550, and 1625 nm. NFO also has options on dynamic ranges so users can select the most cost effective units for their demands. Radiantech provides an easy use API (Application Program Interface) for NFO so users can design and build their own AP for NFO. Standard NFO API package is for Windows XP or higher. Please contact Radiantech’s sales person to inquire API for another OS.

  • GaiaField-Pro Hyperspectral Imaging Camera

    ZOLIX

    YoGaiaField-Pro (GFP) camera provide extremely high resolution images by scanning and taking multiple images to construct a hyperspectral datacube. Hyperspectral imaging devices (GFP) for spatial (slit) scanning obtain slit spectra by projecting a strip of the scene onto a slit and dispersing the slit image with a prism or a grating. In spatial (slit) scanning, each two-dimensional (2-D) sensor output represents a full slit spectrum (x,λ). The NUC integrated into the system to control system operation ,data acquisition, and analyze, so the spatial dimension is collected through the scanning motor movement . The line-scan systems are particularly common in remote sensing, so it is sensible to use mobile platforms. The system can keep working by internal battery about 4 hours and user can use ipad or phone to connect the camera by internal Wifi.

  • Integrated Video Management System

    iVMS - IneoQuest

    The iVMS iQ Engines provide that comprehensive view of your FoQus platform assets. Management systems are available for Linear/IPTV networks (iVMS) or adaptive bitrate networks (iVMS ASM). iVMS tracks QoE and QoS data for thousands of programs across hundreds of acquisition elements to provide true end-to-end, centralized video quality management. With iVMS, you can drill down to identify and isolate the root cause of issues by program, time and location. In order to reduce repair time (MTTR), iVMS can send alert notifications via email to technicians, operations, and engineering staff, and can present collected information to OSS/BSS systems via a northbound interface. iVMS also collects and stores statistics, supporting historical network performance analysis in addition to its real-time capabilities.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • Chemiluminescence Ammonia Analyzer​​​​

    Model T201 - Teledyne Monitor Labs

    The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.The Model T201 achieves its remarkable stability by means of an AutoZero valve which measures and corrects for zero noise. Multiple self-checks are performed continuously to insure maximum up-time while an innovative sample path, plumbed with specially conditioned materials, preserves the NH3 sample and reduces interferents to a minimum. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.The Model T201 comes with the Numaview™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.​​

  • Ultra-Low Range ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300U - Teledyne Monitor Labs

    The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • Ruggedized PC104+ & PCIe/104 System

    Dragon - Excalibur Systems, Inc.

    Excalibur’s Dragon is an advanced, ruggedized PC104 and PC104+ system in an enclosed, modular casing. The system is appropriate for use in data acquisition, recording nd control for any combination of ARINC-429, MIL-STD-1553, Serial, Discrete or similar types of communication. The modular, stack through design of the PC104/PC104+ platform allows you to build a tailor-made configuration based on Excalibur’s extensive range of boards plus any 3rd party cards of the customer’s choosing. Our engineers will integrate and test all 3rd party cards to the customer’s specification.

  • Vibration Control & Analysis System

    APEX SL - Unholtz-Dickie Corporation

    APEX SL offers the latest technology in digital signal processing and shaker control algorithms providing real time vibration test control for random, sine, shock, SRS, random on random, multi-tone sine on random, TRAC (time replication acceleration control) vibration testing and transducer calibration, a well as extensive data acquisition and analysis. The modular software may be initially customized for specific applications or easily expanded in the future without performance penalties. It provides an abundance of comprehensive features that ensure simple, safe, accurate and reliable testing.

  • Engineering Design & Development

    TPS Associates, Inc.

    TPSA has over 20 years of experience in Engineering Design & Software Development including:Hardware & Software DesignOTPS Acquisition SupportSystems Installation & SupportAircraft Modification/CertificationEngineering Studies & AnalysesFunctional & Systems TestingIndependent Verification & Validation (IV & V)Test Program Set EngineeringReliability & Maintainability (R&M)Engineering Drawings & DataConfiguration Data ManagementReverse EngineeringRequirements AnalysisSupport Equipment (SE)Aircraft Launch & Recovery Engineering (ALRE)Engineering Change Proposal (ECP) ReviewTechnology Insertion (TI)PDR, CDR, FAT, Techeval, OSV Support

  • PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays

    M9101A - Keysight Technologies

    The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.

  • PXIe-8821, 2.6 GHz Dual Core Processor PXI Controller

    787895-33 - NI

    PXIe, 2.6 GHz Dual Core Processor PXI Controller - The PXIe‑8821 is an Intel Core i3‑based embedded controller for PXI systems. You use it to create a compact and/or portable PC-based platform for industrial control, data acquisition, and test and measurement applications. The PXIe‑8821 includes a 10/100/1000 BASE‑TX (Gigabit) Ethernet port, two Hi‑Speed USB ports, two USB 3.0 ports, as well as an integrated hard drive, serial port, and other peripheral I/O.

  • PXIe-8821, 2.6 GHz Dual Core Processor PXI Controller

    785158-33 - NI

    PXIe, 2.6 GHz Dual Core Processor PXI Controller—The PXIe‑8821 is an Intel Core i3‑based embedded controller for PXI systems. You use it to create a compact and/or portable PC-based platform for industrial control, data acquisition, and test and measurement applications. The PXIe‑8821 includes a 10/100/1000 BASE‑TX (Gigabit) Ethernet port, two Hi‑Speed USB ports, two USB 3.0 ports, as well as an integrated hard drive, serial port, and other peripheral I/O.

Get Help